Solicitation · 36C24227R0008
NRM CONST - 528A7-18-707 - Replace Boiler Stack Rome CBOC
Department of Veterans Affairs in Albany, NY is taking offers on this bid: NRM CONST - 528A7-18-707 - Replace Boiler Stack Rome CBOC. Offers are due December 2, 2026, 10:00 AM. The official notice on SAM.gov has the documents and says how to send an offer.
Data checked November 28, 2026 against SAM.gov.
- Agency
- Department of Veterans Affairs Federal242-NETWORK Contract Office 02 (36C242)
- Place
- Albany, NY
- Offers due
- December 2, 2026, 10:00 AM (ET) closes in 4 days
- Estimated value
- not stated
- Notice type
- Solicitation
- Category
- Maintenance and repair
- Product service code (PSC)
- Z1DA
- Posted
- November 20, 2026
- Solicitation number
- 36C24227R0008
Opens the notice on SAM.gov, with its attachments and how to respond.
Black Friday: 1 year of same-day bid alerts for $32
Price of 4 months (normally $96). Up to 50 alerts, unlimited search, no renewal. Ends 30 Nov.
Source: SAM.gov Contract Opportunities, the U.S. government's official list of federal contract opportunities.
What is this bid for?
CONTINUATION OF SF 30 BLOCK 14 AMENDMENT DESCRIPTION 0002 AGAINST SOLICITATION NO. 36C24227R0008 1. This amendment answers the following vendor questions: Number of boiler vents: On M-101 (Boiler and Generator Exhaust Plan, Phase II), the new wall penetration/chase is labeled with two 14" I.D. pipes and one 12" I.D. pipe. Keynote 2 calls for a single "new 14" boiler double walled insulated vent stack," and the cutover notes describe that one vent connecting to Boiler #1 and continuing to within two feet of Boiler #2's vent, so one common 14" vent appears to serve both boilers. The solicitation description, however, refers to "two new steel boiler exhaust stacks." Please confirm whether the work is: (a) one 14" double-wall vent common to Boiler #1 and Boiler #2, plus the 12" generator exhaust, or (b) two separate 14" double-wall vents (one per boiler), plus the 12" generator exhaust. If (a), please confirm what the second 14" pipe shown at the penetration represents. Answer: Confirming: it is (b) two separate 14" double-wall vents (one per boiler), plus the 12" generator exhaust. b) Draft control or stack fan: No stack fan, draft inducer, or boiler-outlet draft control appears on the drawings. Section 23 51 00 (paragraph 2.2, Boiler Outlet Dampers and Accessories) refers to automatic draft control specified in Section 23 09 11, but Section 23 09 11 is not included in the solicitation. Please confirm whether: (a) the new boiler vent is intended to operate on natural draft (no fan or draft control required), or (b) a mechanical draft fan and/or barometric or motorized draft control is expected. If so, please issue Section 23 09 11 or identify the required equipment and control sequence. Answer: Confirming: it is (a) the new boiler vent is intended to operate on natural draft (no fan or draft control required). c) Design heating load and operating water temperatures: Please provide the building design heating load (or recent gas and oil usage or meter data), and the normal heating-water supply and return temperatures for the two existing Fulton Vantage boilers. Return-water temperature sets the flue-gas temperature, which governs the vent sizing and draft calculation. Please also confirm whether the two boilers operate as lead/standby (N+1) or are both required at design load. Answer: Replacing the boiler is not part of the contract. Boilers have inducer fans. There is no stack fan or boiler draft controls to be installed. d) Facility designation: Please confirm whether the Rome CBOC is designated mission-critical under VA Physical Security and Resiliency Design requirements, or otherwise required to keep heating on during a utility outage, as this affects the vent design for both fuels. Answer: Rome CBOC is NOT designated as a Critical/Mission Critical facility. CBOCs are generally outpatient facilities rather than hospitals with inpatient, emergency, surgical, or continuity-of-government functions. Therefore, absent a specific VA risk assessment or designation, the Rome CBOC would not ordinarily be assumed to be mission critical. e) Fuel oil and emergency power: Boiler #2 fires #2 fuel oil as a backup fuel. Please confirm (a) whether the vent must be designed for oil firing on Boiler #2 (and on Boiler #1, if applicable), (b) the size and required reserve of the existing #2 oil tank, and (c) whether the boilers and their associated vent or draft equipment are served by emergency power through an automatic transfer switch. Answer: The specified vent material (AL-29-4C) is compatible for operating the boilers on natural gas or #2 oil. This contract does not include altering the existing fuel oil tank, day tank, the boilers, or the generator. We are eliminating the existing exhaust stack and installing a new exhaust stack in a different location to serve the two existing boilers and existing emergency generator. All other terms and conditions remain unchanged.
Questions about this bid
When are offers due for 36C24227R0008?
Offers are due December 2, 2026, 10:00 AM (closes in 4 days).
Which agency is buying, and where?
Department of Veterans Affairs in Albany, NY. BidFinder lists 474 open federal bids from this agency right now.
How do I submit an offer?
Open the official notice on SAM.gov: it has the documents and the instructions for responding.
Is this bid still open?
Yes, it is listed as open here. BidFinder last read it from SAM.gov on November 28, 2026.
Where can I find more bids like this?
- All bids from Department of Veterans Affairs (Albany, NY)474
- Federal maintenance and repair bids in New York39
- Maintenance and repair: every open bid1,027
- Open bids under NAICS 238220 (Plumbing, Heating, and Air-Conditioning Contractors)92
- Open bids in Albany, NY33
- Open bids in New York168
- Bids closing in 7 days
What else is this agency asking for?
- closes in 16 days
- closes in 20 days
- closes in 13 days
- closes in 11 days
- closes in 6 days
Which similar bids are open?
- closes in 10 days
- closes in 10 days
- closes in 5 days
- closes in 2 days
- closes in 2 days
- closes in 25 days
- closes in 9 days
- closes in 4 days
- closes in 9 days
- closes in 10 days